GYRC-ZN01-4P WiFi MCB-Wireless Circuit Breaker with Remote Control

The GYRC-ZN01-4P WiFi MCB is a smart miniature circuit breaker that integrates IoT technology for advanced electrical safety and remote monitoring. With support for WiFi communication and RS485 control, it offers efficient overload, short circuit, and leakage protection. This device is designed for industrial, commercial, and residential applications, meeting modern energy management needs.

  • Poles:4P
  • Rated voltage: single phase AC230V
  • Rated current:32A 、63A 、100A
  • Breaking capacity:Icu = Ics = 6KA
  • Remote automatic reclosing
  • Flame retardant material
  • 4G、WIFI、RS485

→ Download the GYRC series WiFi Smart Circuit Breaker MCB catalog

Description

GYRC-ZN01 WiFi MCB Protection Functions

  • WiFi Remote Monitoring and Protection: Monitor breaker status via WiFi and respond to faults quickly.
  • Overvoltage Protection: Trips when voltage exceeds preset levels (default: 280V).
  • Undervoltage Protection: Trips when voltage drops below preset levels (default: 165V).
  • Overload Protection: Detects excessive current flow, preventing overheating and damage.
  • Short Circuit Protection: 6KA breaking capacity ensures quick response to short circuits.
  • Leakage Protection: Trips when leakage current reaches the set threshold, preventing electric shock.
  • High-Temperature Protection: Trips when temperature exceeds the set value (default: 80°C).
  • Voltage and Current Imbalance Protection: Ensures stable power supply and prevents equipment damage.

GYRC-ZN01 WiFi MCB Offers Flexible Communication Capabilities

  • WiFi Communication: Real-time monitoring and control via a mobile app.
  • RS485 Communication: Compatible with industrial control systems and computers.
  • Default Baud Rate: 9600bps (adjustable in settings).

GYRC-ZN01-4P WiFi MCB Installation and Usage

  • Wiring: Ensure correct connection of live, neutral, and PE lines. Reverse wiring is strictly prohibited.
  • SIM Card (if applicable): Insert the SIM card securely before powering on the device.
  • Parameter Settings: Configure protection values (e.g., overvoltage, undervoltage, leakage) via the LCD screen or app.
  • WiFi Configuration: Connect to WiFi following the user manual instructions.
  • Leakage Test: Test the leakage protection function monthly using the dedicated test button.

Applications

  • Industrial: Protect factory equipment with remote monitoring and management.
  • Commercial: Manage power usage in offices, malls, and data centers.
  • Residential: Smartly monitor and protect home electrical systems via WiFi for enhanced safety.

How to Operate

  • WiFi Control: Download the official app, connect the device to WiFi, and manage it remotely.
  • Manual Operation: Use the handle to manually open or close the breaker.
  • LCD Display: View real-time status, fault alerts, and protection parameter settings.

A Wifi Breaker with Energy Monitoring in TUYA APP Interface:

ZN01 Control      ZN01 VA Measurement Page

Product installation precautions:

1. Reverse connection of product inlet and outlet lines is absolutely not allowed;

2. After installing the product, check if the wiring is correct? Pay special attention not to connect N and PE incorrectly;

3. The leakage function of the product is not allowed to be turned off. Set the leakage parameter value to 30mA (recommended), which can be set to 30mA according to actual application scenarios;

4. For online products, please download and install the APP and scan the QR code on the product;

5. This product’s RS485 is a standard communication port that can be connected to computers and various communication devices through an RS485 to USB converter to achieve information exchange and control;

6. The default Baud of the device is 9600bps. You can view and set the required Baud in the set communication menu;

For 7G and 4G versions of products, a SIM card must be inserted before use to achieve remote information exchange control;

8. Product installation and debugging must be carried out by professional electricians;

9. This product can be customized according to user needs. Please contact relevant technical personnel for details;

10. For special purposes, please consult the manufacturer and service hotline;

 

Feature Specification
Product Information
Product Number GYRC-ZN01-100AP Wifi MCB
Design Number 100A
Frame Grade 100
Pole 4P
Rated Current 32A
Communication Method 4G-RS485
Reclosing Fully Automatic
Technical Specifications
Compliant With GBT 16917 CQC1149
Rated Voltage Single-phase AC230V/Three-phase AC400V 50Hz
Rated Current 32A, 63A, 100A
Trip Type C Type (Other types can be customized)
Short Circuit Breaking Capacity Icu=6kA
Mechanical Life More than 12000 times
Electrical Life More than 6000 times
Closing Time Less than 1.5s
Opening Time Less than 0.1s
Measuring Accuracy 1.0
Leakage Action Value 30, 50, 100, 200, 300, 500mA Optional
Protection Functions
Overvoltage Protection Trip/Off, Adjustable 250-350V (Default 280V), 0-10s Delay (Default 3s)
Undervoltage Protection Alarm/Trip/Off, Adjustable 110-200V (Default 165V), 0-10s Delay (Default 3s)
Phase Loss Protection Not Available
Overload Protection Trip/Off, Adjustable 0.6In – In (Default In), 0-10s Delay (Default 3s)
High Temperature Protection Alarm/Trip/Off, Adjustable 60-100°C (Default 80°C), 0-10s Delay (Default 5s)
Early Warning On/Off
Underload On/Off
Alarm Allowed On/Off
Over Power Protection Off/On, Adjustable 50-50kW (Default 2kW), 0-10s Delay (Default 5s)
Under Power Protection Off/On, Adjustable 50-50kW (Default 2kW), 0-10s Delay (Default 5s)
Timing Control Setting/Off/On
Leakage Protection Trip/Alarm/Off, Adjustable ±0.06/0.1/0.2mA – 100mA (Default 30mA), 30/50/100/200/300/500mA Setting Value
Leakage Mutation Value Adjustable 30-100mA (Default 30mA)
Automatic Reclosing Off/On/Alarm/Trip
Power Failure Trip/Off
Power-off voltage value 0-100V (Default 80V)
Power-off voltage delay 0-5s (Default 2s)
Voltage Unbalance Not Available
Phase Failure Turn Off
Voltage Imbalance Turn Off/Alarm/Trip, 5%-30% (Default 20%), 0-10s Delay (Default 5s)
Current Unbalance Turn Off/Alarm/Trip, 5%-30% (Default 20%), 0-10s Delay (Default 5s)
Timed Turn Off/Turn On
Trial trip hour 23
Trial trip minute 30
Open gear return Turn Off/Alarm/Trip
Open circuit delay 5-600s (Default 60s)
PE alarm Turn Off/Alarm/Trip
Poweron Turn Off/Alarm/Trip
Circuit allowed Off/On
Failure circuit delay 3-20s (Default 3s)
Manual and delay Off/On
Failure delay 0-9
Mechanical lock Yes
Automatic inspection Yes

 