GYR10NE Residual Current Operated Circuit Breaker 1P+N Type A Type AC

The GYR10NE residual current operated circuit breaker is designed for AC 50/60Hz circuits with rated voltage up to 240V and current up to 40A. It integrates residual current protection, overload protection, and short-circuit protection into one device. When a leakage current or electric shock occurs, or when the leakage current exceeds the set value, the GYR10NE quickly disconnects the faulty circuit within a very short time, ensuring reliable protection for both people and electrical equipment. It is suitable for industrial, commercial, high-rise, and residential applications.

  • Rated Voltage (Un):230/240V
  • Rated Current (In):6A,10A,16A,20A,25A,32A,40A
  • Rated Impulse Withstand Voltage (Uimp):4KV
  • Rated Residual Operating Current (I△n):0.03A、0.1A、0.3A

→ Download GYR10NE Residual Current Operated Circuit Breaker Manual PDF

Description

GYR10NE Residual Current Operated Circuit Breaker Product Highlight:

All-in-One Triple Protection: Combines residual current (leakage), overload, and short-circuit protection in a single compact unit to address multiple electrical risks.

Ultra-Compact Design: With a slim 18mm width, it saves valuable space in distribution panels while maintaining high performance.

Fast Response Safety: Leakage tripping time is as quick as 0.04s. At 1x the rated residual current, the disconnection time is less than 0.1s, cutting off power instantly in dangerous situations.

User-Friendly Operation: Specially designed handle with anti-slip grip for comfortable use. Equipped with ON/OFF position indicators for clear visibility of switch status.

High Wiring Capacity: Supports cables up to 16mm², ensuring firm and reliable connections.

 

Technical Parameters Parameter Value
Rated Voltage (Un) 230V/240V
Rated Current (In) 6A,10A,16A,20A,25A,32A,40A
Rated Insulation Voltage (Ui) 500V
Rated Impulse Withstand Voltage (Uimp) 4KV
Rated Residual Operating Current (I△n) 0.03A、0.1A、0.3A
Pole Number 1P+N
Residual Current Operating Type Type A, Type AC
Operating Frequency 50/60 Hz
Rated Limited Short-Circuit Current (Inc) 6000A
Rated Limited Residual Short-Circuit Current (Ic) 6000A
Rated Making and Breaking Capacity (Im) 500A
Rated Residual Making and Breaking Capacity (I△m) 500A
Tightening Torque 1.2N.m
Degree of Protection (IP Rating) IP20
Tripping Curve B、C
Mounting Method TH35-7.5 type standard guide rail

Residual Current Operating Breaking Time

Rated Current In(A) Rated Residual Operating Current I△n(mA) Residual current breaking time (s)
I△n 2I△n 5I△n 5A-200A 500A
6-40 0.03、0.1、0.3 ≤0.1 ≤0.08 ≤0.04 ≤0.04 ≤0.04

Outline and installation dimensions (mm)

Outline and installation dimensions (mm)

Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog