GYR9NE-ARC Arc Fault Detection Device AFDD 1P+N 30ma 6kA

GYR9NE-ARC series arc fault detection device are widely used in household and similar AC circuits with a rated current of 40A and below.

The arc fault protection unit of GYR9NE-ARC series,can detect and identify the series arc fault, parallel arc fault and ground arc fault in circuits;For example: the aging, damage and humidity of the insulation layer of the line are prone to arc fault. When the GYR9NE-ARC series arc fault detection device detects that there is an arc fault in the line, it will automatically trip and cut off the power.

  • pole number: 1P+N;
  • Breaking capacity: 6kA
  • Rated current (A): 6, 10, 16, 20, 25, 32, 40;
  • Rated residual current (mA): 30, 100, 300;
  • Compliant with:IEC/EN62606、IEC/EN61009-1、GB/T31143、1

→ Download GYR9NE-ARC catalog

SKU GYR9NE-ARC Category

Description

Description:

The GYR9NE-ARC series AFDD is an advanced arc fault detection and protection solution. As a modular residual current breaker with overcurrent protection (RCBO), it combines fire prevention technology with robust electrical safety for residential and commercial AC circuits (rated up to 40A). This 1P+N circuit breaker intelligently detects and distinguishes between normal operational arcs (e.g., from switches) and dangerous series, parallel, or ground fault arcs—automatically cutting off power within milliseconds to eliminate fire risks.

Key features include integrated leakage protection (30mA/100mA/300mA sensitivity, Type A/AC) and overvoltage detection (275±5% tolerance), ensuring comprehensive protection against electrical hazards. With a Type C tripping curve and 6kA breaking capacity, it responds instantly to overloads, short circuits, and ground faults while complying with IEC/EN62606, IEC/EN61009-1, GB/T31143, and GB16917.1 standards.

Technical Parameters:

Compliant with IEC/EN62606IEC/EN61009-1GB/T31143GB16917.1
Rated voltage Ue 230V~
Rated insulation voltage Ui 400V
Rated impulse withstand voltage Uimp 4kV
Rated current (A) 6, 10, 16, 20, 25, 32, 40
Pole number 1P+N
Instantaneous trip type C
Breaking capacity 6kA
Rated residual current (mA) 30, 100, 300
Operating characteristics when the residual current has DC component type AC, type A

Technical Parameters
Compliant with IEC/EN62606IEC/EN61009-1GB/T31143GB16917.1
Rated voltage Ue 230V~
Rated insulation voltage Ui 400V
Rated impulse withstand voltage Uimp 4kV
Rated current (A) 6, 10, 16, 20, 25, 32, 40
Pole number 1P+N
Instantaneous trip type C
Breaking capacity 6kA
Rated residual current (mA) 30, 100, 300
Operating characteristics when the residual current has DC component type AC, type A

Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog