GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions

Building upon integrated overvoltage and undervoltage protection, the GPS8-02 Over Voltage Protector adds an adjustable overcurrent protection function (range: 1–80A, delay: 2s–600s), offering triple-layer safety to comprehensively address voltage and current anomalies in complex circuit environments. Equipped with a dual-bus design, auto-reset mechanism, and wide temperature adaptability (-20°C to +60°C), its compact size and DIN rail mounting make it a robust protection solution, especially suitable for industrial equipment or high-precision load scenarios.

  • Rated supply voltage: AC220V(L-N)
  • Operation voltage range: 80V~400V(L-N)
  • Rated operational current: 32A,40A,50A,63A,80A(AC1)
  • Function: Over voltage, under voltage and over current
  • Over current operation value: 1~32A,40A,50A,63A,80A
  • Over current action delay: 2s~600s

→ Download GPS8-02 Catalog PDF

Description

Product Description:

The GPS8-02 Over Voltage Protector is designed for industrial and high-load complex environments. Building on over-voltage and under-voltage protection, it adds an adjustable overcurrent protection feature, delivering comprehensive triple protection for voltage and current. Its flexible overcurrent settings precisely accommodate the dynamic load requirements of equipment such as motors and inverters. Combined with wide voltage input, dual-bus design, and a self-reset mechanism, the GPS8-02 ensures stable performance even in harsh environments ranging from -20°C to +60°C. With its compact size and DIN rail mounting, it is an ideal choice for high-security applications such as industrial production lines and data centers, offering full protection against risks like circuit overloads and short circuits to safeguard system continuity and extend equipment lifespan.

Technical parameters:

Model GPS8-02 Over Voltage Protector
Function Over voltage, under voltage and over current
Rated supply voltage AC220V(L-N)
Rated supply frequency 45~65HZ
Operation voltage range 80V~400V(L-N)
Rated operational current 32A,40A,50A,63A,80A(AC1)
Burden AC max.3VA
Over voltage operation value OFF,230V~300V
Under voltage operation value 140V~210V,OFF
Over/under voltage action delay 0.1s~10s
Over current operation value 1~32A,40A,50A,63A,80A
Over current action delay 2s~600s
Power-up delay 2s~600s
Reset time 2s~900s
Measurement error ≤1%
Electrical life(AC1) 1*104
Mechanical life 1*106
Operating temperature -20℃ ~ +60℃
Storage temperature -35℃ ~ +75℃
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category
Pollution degree 2
Dimensions 82×36×68mm
weight 135g

Functions Diagram:

GPS8 Functions Diagram

Example:

GPS8 Example

Dimensions(mm):

GPS8 Dimensions(mm)

Model GPS8-02
Function Over voltage, under voltage and over current
Rated supply voltage AC220V(L-N)
Rated supply frequency 45~65HZ
Operation voltage range 80V~400V(L-N)
Rated operational current 32A,40A,50A,63A,80A(AC1)
Burden AC max.3VA
Over voltage operation value OFF,230V~300V
Under voltage operation value 140V~210V,OFF
Over/under voltage action delay 0.1s~10s
Over current operation value 1~32A,40A,50A,63A,80A
Over current action delay 2s~600s
Power-up delay 2s~600s
Reset time 2s~900s
Measurement error ≤1%
Electrical life(AC1) 1*104
Mechanical life 1*106
Operating temperature -20℃ ~ +60℃
Storage temperature -35℃ ~ +75℃
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category
Pollution degree 2
Dimensions 82×36×68mm
weight 135g
Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog