The GPS8-10 Adjustable Voltage Protector is equipped with integrated overvoltage, undervoltage, overcurrent, and leakage protection functions. A dedicated metering chip ensures that measurement errors for electrical parameters (such as power and energy consumption) are within ±1%. It features an LCD display for real-time monitoring. Users can customize overvoltage/undervoltage thresholds, overcurrent values, and action delays to meet diverse application needs.

  • Function: Over voltage, under voltage and over current
  • Rated supply voltage: AC220V(L-N)
  • Operation voltage range: 80V~400V(L-N)
  • Rated operational current: 32A,40A,50A,63A,80A(AC1)

→ Download GPS8-10 Catalog PDF

Description

Product Description:

The GPS8-10 Adjustable Voltage Protector  is specifically designed for residential and small-scale electrical environments. With a wide input voltage range (80 V–400 V) and rated current compatibility from 32 A to 80 A, it can reliably handle grid fluctuations and protect household appliances from undervoltage, overvoltage, and overcurrent damage—making it especially well suited for areas with unstable voltage. Its high‑precision monitoring (accuracy ≤ 1 %) and built‑in LCD display intuitively show real‑time data such as power and energy consumption. Thanks to flexible threshold settings (adjustable overvoltage: 230 V–300 V; undervoltage: 140 V–210 V) and intelligent auto‑reset, users can tailor protection strategies to their needs, thereby reducing downtime and maintenance costs.

Technical Parameters:

Model GPS8-10 Adjustable Voltage Protector
Function Over voltage, under voltage and over current
Rated supply voltage AC220V(L-N)
Rated supply frequency 45~65HZ
Operation voltage range 80V~400V(L-N)
Rated operational current 32A,40A,50A,63A,80A(AC1)
Burden AC max.3VA
Over voltage operation value OFF,230V~300V
Under voltage operation value 140V~210V,OFF
Over/under voltage action delay 0.1s~10s
Over current operation value 1~32A,40A,50A,63A,80A
Over current action delay 2s~600s,802.11 b/g/n 2.4GHz
Leakage current value OFF,10mA~400mA
Leakage reclosing count OFF,1~20,ON
Power-up delay 2s~600s
Reset time 2s~900s
Measurement error ≤1%
Electrical life(AC1) 1*104
Mechanical life 1×106
Operating temperature -20℃ ~ +60℃
Storage temperature -35℃ ~ +75℃
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category â…¢
Pollution degree 2
Dimensions 82×54×68mm
weight 205g

Wiring Diagram and Dimensions(mm):

 Wiring Diagram and Dimensions

Functions Diagram:

Functions Diagram

Model GPS8-10
Function Over voltage, under voltage and over current
Rated supply voltage AC220V(L-N)
Rated supply frequency 45~65HZ
Operation voltage range 80V~400V(L-N)
Rated operational current 32A,40A,50A,63A,80A(AC1)
Burden AC max.3VA
Over voltage operation value OFF,230V~300V
Under voltage operation value 140V~210V,OFF
Over/under voltage action delay 0.1s~10s
Over current operation value 1~32A,40A,50A,63A,80A
Over current action delay 2s~600s,802.11 b/g/n 2.4GHz
Leakage current value OFF,10mA~400mA
Leakage reclosing count OFF,1~20,ON
Power-up delay 2s~600s
Reset time 2s~900s
Measurement error ≤1%
Electrical life(AC1) 1*104
Mechanical life 1×106
Operating temperature -20℃ ~ +60℃
Storage temperature -35℃ ~ +75℃
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals