GRLE8-01 Earth Leakage Relay AC 30ma-30A

The GRLE8-01 Earth Leakage Relay combines precision, flexibility, and durability, featuring a wide current range, customizable settings, and an advanced LED indication system to ensure safety and reliability for your electrical systems. This versatile relay is designed for both single-phase and three-phase power systems, making it ideal for applications such as elevators, variable-frequency air conditioners, electric vehicle charging stations, and industrial control systems.

  • Voltage range:AC85-265V 50/60Hz
  • Operation range:30,100,300,500mA and 1,3,5,10,20,30A
  • Trip level limits:85% of setvalue
  • Trip time delay:0,0.15,0.25,0.5,1,2,3,5,7.5,9sec NA when leakage level set 30mA

→ Download GRLE8-01 Earth Leakage Relay Manual PDF

Category

Description

 GRLE8-01 Earth Leakage Relay

GRLE8-01 Earth Leakage Relay Product Highlight:

Comprehensive Residual Current Detection

  1. Type A Compliance: Reliably detects sinusoidal AC and pulsating DC residual currents, suitable for modern inverters and rectifier equipment.
  2. Wide Current Range: Covers leakage currents from 30mA to 30A with high accuracy (±5%), ensuring precise protection.

Customizable Protection Settings

  1. 10 Adjustable Trip Levels: Offers settings at 30mA, 100mA, 300mA, 500mA, 1A, 3A, 5A, 10A, 20A, and 30A to meet diverse application needs, including main protection, branch protection, or fire monitoring.
  2. 9 Adjustable Delay Times: Selectable at 0s, 0.15s, 0.25s, 0.5s, 1s, 2s, 3s, 5s, 7.5s, and 9s, enabling precise coordination with upstream protection to prevent false tripping and ensure power continuity.
  3. 30mA Mandatory Zero Delay: When set to the most sensitive 30mA (personal safety protection level), the relay trips instantly without delay, rapidly cutting off power to safeguard lives.

Advanced Monitoring and Indication

  1. Four-Stage LED Warning System: LEDs illuminate steadily when leakage current reaches 25%, 50%, or 75% of the set value, clearly indicating leakage trends; the fourth LED signals trip status.
  2. ZCT Detection: When the residual current transformer (ZCT) encounters an error, LEDs ①②③④ flash continuously.

Robust and Durable Design

  1. Wide Voltage Range: Operates reliably under grid voltage fluctuations of AC 85-265V (50/60Hz).
  2. Flexible Reset Modes: Supports manual and automatic reset (via Y1-C connection) to meet diverse operational needs.
  3. DIN Rail Installation: Compact size (90mm × 36mm × 64mm) for easy installation.
  4. High Durability: Mechanical lifespan of 1×10^7 cycles and electrical lifespan (AC1) of 1×10^5 cycles, ensuring long-term reliable performance.

GRLE8-01 Earth Leakage Relay Application

Application Scenarios

The GRLE8-01 Earth Leakage Relay is designed for a variety of applications, including:

  • Elevators: Ensures leakage safety in complex control systems.
  • Variable Frequency Drive Equipment: Protects inverters and rectifiers in variable frequency air conditioners and industrial equipment.
  • Electric Vehicle Charging Stations: Provides safe and efficient leakage protection.
  • Industrial Control Systems: Enhances safety in automated and high-power environments.

GRLE8-01 wiring diagram 1

Technical Parameters

Model GRLE8-01 Earth Leakage Relay
Function Earth leakage Relay
Supply terminals A1-A2
Voltage range AC85-265V 50/60Hz
Burden 3VA
Operation range 30,100,300,500mA and 1,3,5,10,20,30A
Trip level limits 85% of setvalue
Trip time delay 0,0.15,0.25,0.5,1,2,3,5,7.5,9sec
NA when leakage level set 30mA
Reset time ~2sec
Response time ≤30ms(if trip current≥5×I△n)
≤50ms(if trip current=1×I△n)
Reset value 85% of trip level
ZCT detection absent or short
Accuracy Trip:±5% of set trip current
Time:±5% of set time±50ms
Reset mode Manual/Auto reset
Output 1 SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Mechanical life 1×10^7
Electrical life(AC1) 1×10^5
Operating temperature -20℃~+55℃
Storage temperature -35℃~+75℃
Humidity Up to 95% RH(non-condensing)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP20
Operating position any
Overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm²) 1×2.5mm² or 2×1.5mm²  0.4N·m
Dimensions 90mm×36mm×64mm
Standards IEC 60947-2

Panel Diagram:

Panel Diagram

Wiring Diagram:

Wiring Diagram

Function:

Function

Dimensions:

Dimensions

Accessory:

Accessory

Contact Us
Contact Us

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog