GYM10 combination 01

GYM 10 MCB Circuit Breaker

Choose Your Perfect Fit:

    • Rated Current: 1A – 63A
    • Rated Voltage: AC 230V/400V
    • Poles: 1P / 2P / 3P / 4P
    • Breaking Capacity: 3kA / 4.5kA / 6kA

The GYM10 series miniature circuit breaker combines precision engineering with robust safety features to deliver unwavering protection for your electrical systems. With advanced C65 technology, the GYM10 ensures accurate overload and short-circuit protection, minimizing nuisance tripping and maximizing operational uptime.

  • Explore the GYM10 series below and find the ideal solution to confidently safeguard your electrical systems.

Discover the GYM10 Circuit Breaker Advantages:

Comparison of GYM10 false tripping rate

GYM10 MCB Technical Specifications:

ParameterValue
Rated Current1A – 63A
Rated VoltageAC 230V/400V
Breaking Capacity3kA / 4.5kA / 6kA
Number of Poles1P / 2P / 3P / 4P
Mounting TypeDIN Rail Mounting
Mechanical Life20,000 cycles
Electrical Life10,000 cycles

Catalog Download

A German power company

In order to improve the stability and safety of the production line, a large manufacturing enterprise chose to replace the original circuit breaker with GYM10 series. After the replacement, the failure rate of the equipment was reduced by 15%, which effectively improved the production efficiency and also reduced the maintenance cost, which was highly recognized by the customer.

Quick Chart Selection

Click on the chart below to select the breaker that’s right for you. (not mandatory)

CurrentVoltageLoad PowerCopper Wire
10A220V2200W1.5MM²
16A220V3520W1.5MM²
20A220V4400W2.5MM²
25A220V5500W2.5MM²
32A220V7040W4.0MM²
40A220V8800W6.0MM²
50A220V11000W10.0MM²
63A220V13860W10.0MM²
Does the GYM10 miniature circuit breaker (MCB) require regular maintenance? How do I do it?

Answer: Yes, to ensure the long-term stable operation of your GYM10 MCB, we recommend regular maintenance. You can refer to the following steps:

  • Regular inspection: It is recommended to conduct a comprehensive inspection of the breaker at least once a year, including visual inspection, mechanical operation inspection, and electrical performance testing.
  • Cleaning: Clean the surface of the breaker with a dry, soft cloth. Avoid using corrosive cleaners.
  • Tightening: Check the wiring terminals of the breaker for looseness and tighten them in time.
  • Record-keeping: Keep maintenance records, recording the maintenance time, items, and results.

Answer: To select the appropriate GYM10 MCB model, consider the following factors:

  • Load current: The rated current of the circuit breaker should be greater than or equal to the load current of the circuit.
  • Voltage level: The rated voltage of the circuit breaker should match the voltage level of the circuit.
  • Breaking capacity: The breaking capacity of the circuit breaker should be greater than the potential short-circuit current of the circuit.
  • Installation method: Choose the appropriate installation method according to the actual installation environment, such as DIN rail mounting or panel mounting.

You can refer to our product selection guide or contact our technical staff for assistance.

Answer: To ensure you are purchasing a genuine GEYA GYM10 circuit breaker, we recommend purchasing through the following channels:

  • Official website: You can find information about our authorized distributors on the GEYA official website.
  • Authorized distributors: We have a global network of authorized distributors. You can find your nearest distributor through our website.
  • E-commerce platforms: We are also present on some well-known e-commerce platforms. You can search for “GEYA GYM10” on the platform to find our products.

Be sure to look for the GEYA brand logo and product packaging to ensure that you are purchasing genuine products.

Answer: GYM10 miniature circuit breakers come with a 2-year warranty. Within the warranty period, if the product experiences quality issues not caused by human factors, you can contact us for free repair or replacement.

Answer: If your GYM10 circuit breaker malfunctions, please disconnect the power supply immediately and contact our after-sales service department. You can contact us through the following ways:

  • Phone: Call our after-sales service hotline, and our technical staff will be happy to assist you.
  • Email: Send an email to our after-sales service mailbox, and we will reply to your questions as soon as possible.
  • Online consultation: You can also contact us through the online customer service system on our website.

Please provide the following information when you contact us:

  • Product model
  • Fault description
  • Contact information

We will solve your problem as soon as possible.

Get a free quote and technical help

Contact Us
Contact Us

Contact US

Check Out The Full Catalog

Quick Info Exchange Helps Us Serve You Better
(Low-voltage and solar energy electrical components catalog)

Electrical Equipment catalog